S7-1500 SIEMENS 6ES7515-2AM01-0AB0
تماس بگیرید
بررسی اجمالی محصول
SIMATIC S7-1500, CPU 1515-2 PN, Central processing unit with work memory 500 KB for Program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30 ns bit performance, SIMATIC Memory Card required
نقد و بررسی : S7-1500 SIEMENS 6ES7515-2AM01-0AB0
S7-1500 SIEMENS 6ES7515-2AM01-0AB0
SIMATIC S7-1500 SIEMENS , CPU 1515-2 PN, Central processing unit with work memory 500 KB for Program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30 ns bit performance, SIMATIC Memory Card required
General information |
|
Product type designation | CPU 1515-2 PN |
HW functional status | FS03 |
Firmware version | V2.8 |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central) |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated as of version | V16 (FW V2.8) / V13 (FW V1.5) or higher |
Configuration control | |
via dataset | Yes |
Display | |
Screen diagonal [cm] | 6.1 cm |
Control elements | |
Number of keys | 6 |
Mode selector switch | 1 |
Supply voltage |
|
Type of supply voltage | 24 V DC |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering | |
● Mains/voltage failure stored energy time | 5 ms |
● Repeat rate, min. | 1/s |
Input current | |
Current consumption (rated value) | 0.8 A |
Inrush current, max. | 2.4 A; Rated value |
I²t | 0.02 A²·s |
Power | |
Infeed power to the backplane bus | 12 W |
Power consumption from the backplane bus (balanced) | 6.2 W |
Power loss | |
Power loss, typ. | 6.3 W |
Memory | |
Number of slots for SIMATIC memory card | 1 |
SIMATIC memory card required | Yes |
Work memory | |
● integrated (for program) | 500 kbyte |
● integrated (for data) | 3 Mbyte |
Load memory | |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup |
|
● maintenance-free | Yes |
CPU processing times | |
for bit operations, typ. | 30 ns |
for word operations, typ. | 36 ns |
for fixed point arithmetic, typ. | 48 ns |
for floating point arithmetic, typ. | 192 ns |
CPU-blocks |
|
Number of elements (total) | 6 000; Blocks (OB, FB, FC, DB) and UDTs |
DB | |
● Number range | 1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999 |
● Size, max. | 3 Mbyte; For DBs with absolute addressing, the max. size is 64
KB |
FB | |
● Number range | 0 … 65 535 |
● Size, max. | 500 kbyte |
FC | |
● Number range | 0 … 65 535 |
● Size, max. | 500 kbyte |
OB |
|
● Size, max. | 500 kbyte |
● Number of free cycle OBs | 100 |
● Number of time alarm OBs | 20 |
● Number of delay alarm OBs | 20 |
● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 500 µs |
● Number of process alarm OBs | 50 |
● Number of DPV1 alarm OBs | 3 |
● Number of isochronous mode OBs | 2 |
● Number of technology synchronous alarm OBs | 2 |
● Number of startup OBs | 100 |
● Number of asynchronous error OBs | 4 |
● Number of synchronous error OBs | 2 |
● Number of diagnostic alarm OBs | 1 |
Nesting depth |
|
● per priority class | 24 |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC counter | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
S7 times | |
● Number | 2 048 |
Retentivity |
|
— adjustable | Yes |
IEC timer | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB |
Extended retentive data area (incl. timers, counters, flags), max. | 3 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
Flag | |
● Number, max. | 16 kbyte |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks |
|
● Retentivity adjustable | Yes |
● Retentivity preset | No |
Local data | |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area | |
Number of IO modules | 8 192; max. number of modules / submodules |
I/O address area | |
● Inputs | 32 kbyte; All inputs are in the process image |
● Outputs | 32 kbyte; All outputs are in the process image |
per integrated IO subsystem |
|
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
per CM/CP | |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
Subprocess images | |
● Number of subprocess images, max. | 32 |
Hardware configuration |
|
Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via ASi master modules or links (e.g. IE/PB-Link) |
Number of DP masters | |
● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Number of IO Controllers | |
● integrated | 2 |
● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Rack | |
● Modules per rack, max. | 32; CPU + 31 modules |
● Number of lines, max. | 1 |
PtP CM | |
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day |
|
Clock | |
● Type | Hardware clock |
● Backup time | 6 wk; At 40 °C ambient temperature, typically |
● Deviation per day, max. | 10 s; Typ.: 2 s |
Operating hours counter | |
● Number | 16 |
Clock synchronization | |
● supported | Yes |
● in AS, master | Yes |
● in AS, slave | Yes |
● on Ethernet via NTP | Yes |
Interfaces | |
Number of PROFINET interfaces | 2 |
1. Interface | |
Interface types | |
● Number of ports | 2 |
● integrated switch | Yes |
● RJ 45 (Ethernet) | Yes; X1 |
Protocols |
|
● IP protocol | Yes; IPv4 |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | Yes |
PROFINET IO Controller | |
Services |
|
— PG/OP communication | Yes |
— S7 routing | Yes |
— Isochronous mode | Yes |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
— IRT | Yes |
— MRP | Yes; MRP Automanager acc. to IEC 62439-2 Edition 2.0; MRP Manager; MRP Client; max. number of devices in the ring: 50 |
— MRPD | Yes; Requirement: IRT |
— PROFIenergy | Yes; per user program |
— Prioritized startup | Yes; Max. 32 PROFINET devices |
— Number of connectable IO Devices, max. | 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
— Of which IO devices with IRT, max. | 64
256 |
— Number of connectable IO Devices for RT, max. | |
— of which in line, max. | 256 |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
— Number of IO Devices per tool, max. | 8 |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
Update time for IRT |
|
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive |
— for send cycle of 500 µs | 500 µs to 8 ms |
— for send cycle of 1 ms | 1 ms to 16 ms |
— for send cycle of 2 ms | 2 ms to 32 ms |
— for send cycle of 4 ms | 4 ms to 64 ms |
— With IRT and parameterization of “odd” send cycles | Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) |
Update time for RT | |
— for send cycle of 250 µs | 250 µs to 128 ms |
— for send cycle of 500 µs | 500 µs to 256 ms |
— for send cycle of 1 ms | 1 ms to 512 ms |
— for send cycle of 2 ms | 2 ms to 512 ms |
— for send cycle of 4 ms | 4 ms to 512 ms |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes |
— S7 routing | Yes |
— Isochronous mode | No |
— IRT | Yes |
— MRP | Yes; MRP Automanager acc. to IEC 62439-2 Edition 2.0; MRP Manager; MRP Client; max. number of devices in the ring: 50 |
— MRPD | Yes; Requirement: IRT |
— PROFIenergy | Yes; per user program |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4 |
— Asset management record | Yes; per user program |
2. Interface | |
Interface types | |
● Number of ports | 1 |
— PROFIenergy | Yes; per user program
No |
— Prioritized startup | |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4 |
— Asset management record | Yes; per user program |
Interface types |
|
RJ 45 (Ethernet) | |
● 100 Mbps | Yes |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Industrial Ethernet status LED | Yes |
Protocols | |
Number of connections | |
● Number of connections, max. | 192; via integrated interfaces of the CPU and connected CPs /
CMs |
● Number of connections reserved for
ES/HMI/web |
10 |
● Number of connections via integrated interfaces | 108 |
● Number of S7 routing paths | 16 |
Redundancy mode | |
● H-Sync forwarding | Yes |
SIMATIC communication |
|
● S7 communication, as server | Yes |
● S7 communication, as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Open IE communication | |
● TCP/IP | Yes |
— Data length, max. | 64 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 64 kbyte |
● UDP | Yes |
— Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
— UDP multicast | Yes; Max. 5 multicast circuits |
● DHCP | No |
● SNMP | Yes |
● DCP | Yes
Yes |
● LLDP | |
Web server |
— Number of server methods, max. | 50
20 |
— Number of inputs/outputs per server method, max. | |
— Number of monitored items, max. | 2 000; for 1 s sampling interval and 1 s send interval |
— Number of server interfaces, max. | 10; or 20, depending on type of server interface |
— Number of nodes for user-defined server interfaces, max. | 5 000 |
Further protocols |
|
● MODBUS | Yes; MODBUS TCP |
Media redundancy | |
● Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
● Number of stations in the ring, max. | 50 |
Isochronous mode | |
Isochronous operation (application synchronized up to terminal) | Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central) |
Equidistance | Yes |
S7 message functions | |
Number of login stations for message functions, max. | 64 |
Program alarms | Yes |
Number of configurable program messages, max. | 10 000; Program messages are generated by the
“Program_Alarm” block, ProDiag or GRAPH |
Number of loadable program messages in RUN, max. | 5 000 |
Number of simultaneously active program alarms
● Number of program alarms |
800 |
● Number of alarms for system diagnostics | 200 |
● Number of alarms for motion technology objects | 160 |
Test commissioning functions |
|
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
Single step | No |
Number of breakpoints | 8 |
Status/control | |
● Status/control variable | Yes |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
● Number of variables, max.
— of which status variables, max. |
200; per job |
— of which control variables, max. | 200; per job |
Forcing |
● Forcing, variables | Peripheral inputs/outputs
200 |
● Number of variables, max. | |
Diagnostic buffer | |
● present | Yes |
● Number of entries, max. | 3 200 |
— of which powerfail-proof | 500 |
Traces | |
● Number of configurable Traces | 4; Up to 512 KB of data per trace are possible |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
● RUN/STOP LED | Yes |
● ERROR LED | Yes |
● MAINT LED | Yes |
● Connection display LINK TX/RX | Yes |
Supported technology objects |
|
Motion Control | Yes; Note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER |
● Number of available Motion Control resources for technology objects (except cam disks) | 2 400 |
● Required Motion Control resources
— per speed-controlled axis |
40 |
— per positioning axis | 80 |
— per synchronous axis | 160 |
— per external encoder | 80 |
— per output cam | 20 |
— per cam track | 160 |
— per probe | 40 |
● Positioning axis |
|
— Number of positioning axes at motion control cycle of 4 ms (typical value) | 7 |
— Number of positioning axes at motion control cycle of 8 ms (typical value) | 14 |
Controller
● PID_Compact |
Yes; Universal PID controller with integrated optimization |
● PID_3Step
● PID-Temp |
Yes; PID controller with integrated optimization for valves |
Yes; PID controller with integrated optimization for temperature | |
Counting and measuring | |
● High-speed counter | Yes |
Ambient conditions |
|
Ambient temperature during operation | |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
0 °C |
● vertical installation, min. | |
● vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40
°C, the display is switched off |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Configuration | |
Programming | |
Programming language |
|
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— GRAPH | Yes |
Know-how protection | |
● User program protection/password protection | Yes |
● Copy protection | Yes |
● Block protection | Yes |
Access protection | |
● Password for display | Yes |
● Protection level: Write protection | Yes |
● Protection level: Read/write protection | Yes |
● Protection level: Complete protection | Yes |
Cycle time monitoring |
|
● lower limit | adjustable minimum cycle time |
● upper limit | adjustable maximum cycle time |
Dimensions | |
Width | 70 mm |
Height | 147 mm |
Depth | 129 mm |
Weights | |
Weight, approx. | 830 g |
last modified: | 01/17/2020 |
-
کنتاکتور 12 آمپر پارس فانال مدل PFC-12
280,000 تومانکنتاکتور 12 آمپر پارس فانال کنتاکتورهای پارس فانال تحت لیسانس فانال آلمان در ایران تولید و به بازار عرض می شود . پارس فانال ارائه دهنده محصولات همچون کنتاکتور - فیوز مینیاتوری - چراغ سیگنال - کلید حرارتی و .... می باشده -
سوکت 4 پین پاور سیم دار
90,000 تومان== Summary == {{Information |Description=Male, 4 pin, Mini-DIN power connector (plug) from a laptop computer power supply cable. |Source=self-made |Date=7/22/2007 |Author= Frogtumor }} -
کلید محافظ جان تک فاز 16 آمپر پارس فانال PFR-2P-16A
تماس بگیریدکلید محافظ جان 16 آمپر پارس فانال مدل PFR-2P-16A آی سی اِس شاپ ارائه دهنده محصولات پارس فانال از جمله کلید محافظ جان پارس فانال جهت مشاهده دیگر محصولات پارس فانال باما همراه باشید -
کنتاکتور 9 آمپر پارس فانال مدل PFC-9
270,000 تومانکنتاکتور 9 آمپر پارس فانال کنتاکتورهای پارس فانال تحت لیسانس فانال آلمان در ایران تولید و به بازار عرض می شود . پارس فانال ارائه دهنده محصولات همچون کنتاکتور - فیوز مینیاتوری - چراغ سیگنال - کلید حرارتی و .... می باشده -
منبع تغذیه 12 ولت 20 آمپر
310,000 تومانمنبع تغذیه 12 ولت 20 امپر (S-240-12) با توان خروجی 240وات تحویلی به مصرف کننده اندازه گیری شده است. ولتاژ ورودی که در این منبع تغذیه قابل قبول است بین 110 ولت تا 220 ولت ac می باشد این دستگاه الکترونیک توانایی تبدیل ولتاژی به ولتاژ دیگری را دارد. -
منبع تغذیه 24 ولت 3 آمپر
تماس بگیریدمنبع تغذیه 24 ولت 3 امپر (S-72-24) با توان خروجی 72 وات تحویلی به مصرف کننده اندازه گیری شده است. ولتاژ ورودی که در این منبع تغذیه قابل قبول است 220 ولت ac می باشد این دستگاه الکترونیک توانایی تبدیل ولتاژی به ولتاژ دیگری را دارد.