S7-1500 SIEMENS 6ES7515-2AM01-0AB0

S7-1500 SIEMENS 6ES7515-2AM01-0AB0


تماس بگیرید

دسته بندی : ,

آخرین بروزرسانی : ۲۰ شهریور, ۱۴۰۳

بررسی اجمالی محصول

SIMATIC S7-1500, CPU 1515-2 PN, Central processing unit with work memory 500 KB for Program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30  ns bit performance, SIMATIC Memory Card required

جهت ارائه خدمات همکاری از قبیل تخفیف همکاری , لیست قیمت و…

خدمات همکاری آی سی اِس شاپـــــــ شامل تامین لوازم و تجهیزات صنعتی (برندهای مطرح دنیا) ، ارائه گارانتی و تعمیر فوری محصولات , مشاوره به همکاران گرامی , ارائه تخفیف همکاری و یا ارسال رایگان محصولات می باشد . (همکاری شمارتو وارد کن تا فرم ثبت نام برات ارسال بشه )

نقد و بررسی : S7-1500 SIEMENS 6ES7515-2AM01-0AB0

S7-1500 SIEMENS 6ES7515-2AM01-0AB0

SIMATIC S7-1500 SIEMENS , CPU 1515-2 PN, Central processing unit with work memory 500 KB for Program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30  ns bit performance, SIMATIC Memory Card required

SIEMENS

General information

Product type designation CPU 1515-2 PN
HW functional status FS03
Firmware version V2.8
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central)
Engineering with
● STEP 7 TIA Portal configurable/integrated as of version V16 (FW V2.8) / V13 (FW V1.5) or higher
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 6
Mode selector switch 1

Supply voltage

Type of supply voltage 24 V DC
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
● Repeat rate, min. 1/s
Input current
Current consumption (rated value) 0.8 A
Inrush current, max. 2.4 A; Rated value
I²t 0.02 A²·s
Power
Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 6.2 W
Power loss
Power loss, typ. 6.3 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 500 kbyte
● integrated (for data) 3 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte

Backup

● maintenance-free Yes
CPU processing times
for bit operations, typ. 30 ns
for word operations, typ. 36 ns
for fixed point arithmetic, typ. 48 ns
for floating point arithmetic, typ. 192 ns

CPU-blocks

Number of elements (total) 6 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999
● Size, max. 3 Mbyte; For DBs with absolute addressing, the max. size is 64

KB

FB
● Number range 0 … 65 535
● Size, max. 500 kbyte
FC
● Number range 0 … 65 535
● Size, max. 500 kbyte

OB

● Size, max. 500 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 500 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 2
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1

Nesting depth

● per priority class 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048

Retentivity

— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Extended retentive data area (incl. timers, counters, flags), max. 3 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Number, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte

Data blocks

● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 8 192; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image

per integrated IO subsystem

— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32

Hardware configuration

Number of distributed IO systems 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via ASi master modules or links (e.g. IE/PB-Link)
Number of DP masters
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated 2
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max. 32; CPU + 31 modules
● Number of lines, max. 1
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots

Time of day

Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes
Interfaces
Number of PROFINET interfaces 2
1. Interface
Interface types
● Number of ports 2
● integrated switch Yes
● RJ 45 (Ethernet) Yes; X1

Protocols

● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller

Services

— PG/OP communication Yes
— S7 routing Yes
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT Yes
— MRP Yes; MRP Automanager acc. to IEC 62439-2 Edition 2.0; MRP Manager; MRP Client; max. number of devices in the ring: 50
— MRPD Yes; Requirement: IRT
— PROFIenergy Yes; per user program
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64

256

— Number of connectable IO Devices for RT, max.
— of which in line, max. 256
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

— for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
— for send cycle of 500 µs 500 µs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of “odd” send cycles Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs)
Update time for RT
— for send cycle of 250 µs 250 µs to 128 ms
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes
— S7 routing Yes
— Isochronous mode No
— IRT Yes
— MRP Yes; MRP Automanager acc. to IEC 62439-2 Edition 2.0; MRP Manager; MRP Client; max. number of devices in the ring: 50
— MRPD Yes; Requirement: IRT
— PROFIenergy Yes; per user program
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— Asset management record Yes; per user program
2. Interface
Interface types
● Number of ports 1
— PROFIenergy Yes; per user program

No

— Prioritized startup
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— Asset management record Yes; per user program

Interface types

RJ 45 (Ethernet)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
● Industrial Ethernet status LED Yes
Protocols
Number of connections
● Number of connections, max. 192; via integrated interfaces of the CPU and connected CPs /

CMs

● Number of connections reserved for

ES/HMI/web

10
● Number of connections via integrated interfaces 108
● Number of S7 routing paths 16
Redundancy mode
● H-Sync forwarding Yes

SIMATIC communication

● S7 communication, as server Yes
● S7 communication, as client Yes
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; Max. 5 multicast circuits
● DHCP No
● SNMP Yes
● DCP Yes

Yes

● LLDP
Web server
— Number of server methods, max. 50

20

— Number of inputs/outputs per server method, max.
— Number of monitored items, max. 2 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max. 10; or 20, depending on type of server interface
— Number of nodes for user-defined server interfaces, max. 5 000

Further protocols

● MODBUS Yes; MODBUS TCP
Media redundancy
● Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
● Number of stations in the ring, max. 50
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central)
Equidistance Yes
S7 message functions
Number of login stations for message functions, max. 64
Program alarms Yes
Number of configurable program messages, max. 10 000; Program messages are generated by the

“Program_Alarm” block, ProDiag or GRAPH

Number of loadable program messages in RUN, max. 5 000
Number of simultaneously active program alarms

● Number of program alarms

800
● Number of alarms for system diagnostics 200
● Number of alarms for motion technology objects 160

Test commissioning functions

Joint commission (Team Engineering) Yes; Parallel online access possible for up to 8 engineering systems
Status block Yes; Up to 8 simultaneously (in total across all ES clients)
Single step No
Number of breakpoints 8
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.

— of which status variables, max.

200; per job
— of which control variables, max. 200; per job
Forcing
● Forcing, variables Peripheral inputs/outputs

200

● Number of variables, max.
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— of which powerfail-proof 500
Traces
● Number of configurable Traces 4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED Yes
● ERROR LED Yes
● MAINT LED Yes
● Connection display LINK TX/RX Yes

Supported technology objects

Motion Control Yes; Note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER
● Number of available Motion Control resources for technology objects (except cam disks) 2 400
● Required Motion Control resources

— per speed-controlled axis

40
— per positioning axis 80
— per synchronous axis 160
— per external encoder 80
— per output cam 20
— per cam track 160
— per probe 40

● Positioning axis

— Number of positioning axes at motion control cycle of 4 ms (typical value) 7
— Number of positioning axes at motion control cycle of 8 ms (typical value) 14
Controller

● PID_Compact

Yes; Universal PID controller with integrated optimization
● PID_3Step

● PID-Temp

Yes; PID controller with integrated optimization for valves
Yes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counter Yes

Ambient conditions

Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off

0 °C

● vertical installation, min.
● vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature of typically 40

°C, the display is switched off

Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Configuration
Programming

Programming language

— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— GRAPH Yes
Know-how protection
● User program protection/password protection Yes
● Copy protection Yes
● Block protection Yes
Access protection
● Password for display Yes
● Protection level: Write protection Yes
● Protection level: Read/write protection Yes
● Protection level: Complete protection Yes

Cycle time monitoring

● lower limit adjustable minimum cycle time
● upper limit adjustable maximum cycle time
Dimensions
Width 70 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 830 g
last modified: 01/17/2020

  • اينورتر 1.5 کیلووات تک فاز اینوت invt سری GD20

    8,523,000 تومان
    آی سی اِس شاپ ارائه دهنده اینورتر invt با ماهمراه باشید با معرفی مشخصات درایو 1.5 کیلووات تک فاز اینوت invt سری GD20 محصولی کوچک و اقصادی 🔺 برند : اینوت invt 🔺 نوع محصول : اينورتر 1.5 کیلووات تک فاز 🔺 کد فنی اینورتر : GD20-1R5G-S2 🔺 سری اینورتر : اينورتر GD20
  • مبدل 110 به 24 ولت 14 آمپر مین ول

    تومان
    کانورتر 24 ولت 14 آمپر مین ول با توان و قدرت 350 وات واقعی در خروجی اندازه گیری شده است. این مبدل DC به DC در دسته کانورتر های کف خواب این شرکت تایوانی قرار می گیرد. راندمان در این منبع تغذیه DC به DC تا عدد بالای 82 در صد می رسد که در صنعت بسیار کاربردی ست. محافظت در برابر اتصال کوتاه، اضافه بار، ولتاژ بالا و درجه…
  • منبع تغذیه 12 ولت 37.5 آمپر مین ول (SE-450-12)منبع تغذیه 12 ولت 37.5 آمپر مین ول (SE-450-12)

    منبع تغذیه 12 ولت 37.5 آمپر مین ول

    تومان
    منبع تغذیه 12 ولت 37.5 آمپر مین ول (SE-450-12) با توان و قدرت 450 وات واقعی اندازه گیری شده است. این منبع تغذیه سوئیچینگ در دسته محصولات کف خواب این شرکت تایوانی قرار می گیرد. راندمان در این منبع تغذیه به عدد بالای 83% می رسد که به راحتی پاسخگوی نیاز کار می باشد. از ویژگی های حفاظتی در این منبع تغذیه می توان به حفاظت در برابر  اتصال كوتاه،…
  • منبع تغذیه 5 ولت 3 آمپر مین ول

    تومان
    منبع تغذیه 5 ولت 3 آمپر مین ول (MDR-20-5) در مجموع با 20 وات واقعی در خروجی اندازه گیری شده است. سری MDR 20 در دسته محصولات ریلی شرکت مین ول قرار می گیرند. بازدهی (راندمان) این کانورتر به عدد بالای 80 درصد می رسد. که پاسخگوی نیاز های مصرف کننده می باشد. از جمله ویژگی های حفاظتی که این محصول داراست میتوان به حفاظت در برابر اتصال کوتاه ،…
  • کانورتر 24 ولت 4.2 آمپر مین ول SD-100B-24کانورتر 24 ولت 4.2 آمپر مین ول SD-100B-24

    مبدل 24 به 24 ولت 4.2 آمپر مین ول

    2,520,000 تومان
    کانورتر 24 ولت 4.2 آمپر (SD-100B-24) مین ول با توان و قدرت 100.8 وات در خروجی اندازه گیری شده است. این کانورتر در دسته مبدل های DC به DC کف خواب شرکت مین ول قرار می گیرد. راندمان این منبع تغذیه (SD-100B-24) تا 78 در صد افزایش پیدا می کند که این مقدار پاسخگو نیاز کاربر می باشد. این مبدل DC به DC (کانورتر) در فیلتر EMI ساخته شده است.…
  • اينورتر 1.5 کیلووات تک فاز اینوت invt سری GD10

    8,037,000 تومان
    آی سی اِس شاپ ارائه دهنده اینورتر invt با ماهمراه باشید با معرفی مشخصات درایو 1.5 کیلووات تک فاز اینوت invt سری GD10 🔺 برند : اینوت invt 🔺 نوع محصول : اينورتر 1.5 کیلووات تک فاز 🔺 کد فنی اینورتر : GD10-1R5G-S2-B 🔺 سری اینورتر : اينورتر GD10