Analog Input Module 6ES7134-6GF00-0AA1
SIMATIC ET 200SP, Analog Input Module , AI 8XI 2-/4-wire Basic, suitable for BU type A0, A1, Color code CC01, Module diagnostics, 16 bit
SIEMENS | |
General information |
|
Product type designation | AI 8xI 2-/4-wire BA |
HW functional status | from FS04 |
Firmware version
● FW update possible |
Yes |
usable BaseUnits | BU type A0, A1 |
Color code for module-specific color identification plate | CC01 |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
● Measuring range scalable | No |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated as of version | V13 SP1 |
● STEP 7 configurable/integrated as of version | V5.5 SP3 / – |
● PROFIBUS as of GSD version/GSD revision | GSD Revision 5 |
● PROFINET as of GSD version/GSD revision | GSDML V2.3 |
Operating mode | |
● Oversampling | No |
● MSI | No |
CiR – Configuration in RUN | |
Reparameterization possible in RUN | Yes |
Calibration possible in RUN | No |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Input current |
|
Current consumption, max. | 25 mA; without sensor supply |
Encoder supply | |
24 V encoder supply | |
● 24 V | Yes |
● Short-circuit protection | Yes |
● Output current, max. | 0.7 A; total current of all encoders/channels |
Power loss | |
Power loss, typ. | 0.7 W; Without encoder supply voltage |
Address area | |
Address space per module | |
● Address space per module, max. | 16 byte |
Hardware configuration | |
Automatic encoding | |
● Mechanical coding element | Yes |
Selection of BaseUnit for connection variants | |
● 1-wire connection | BU type A0, A1 |
● 2-wire connection | BU type A0, A1 |
● 4-wire connection | BU type A0, A1 + potential distributor module |
Analog inputs | |
Number of analog inputs | 8; Single-ended |
● For current measurement | 8 |
permissible input current for current input (destruction limit), max. | 50 mA |
Cycle time (all channels), min. | 1 ms; per channel |
Input ranges (rated values), currents | |
● 0 to 20 mA | Yes |
● Input resistance (0 to 20 mA) | 100 Ω; 15 bit |
● -20 mA to +20 mA | Yes |
● Input resistance (-20 mA to +20 mA) | 100 Ω; 16 bit incl. sign |
● 4 mA to 20 mA | Yes
100 Ω; 15 bit |
● Input resistance (4 mA to 20 mA) | |
Cable length | |
● shielded, max. | 200 m |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 16 bit |
● Integration time, parameterizable | Yes |
● Interference voltage suppression for interference frequency f1 in Hz | 16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60) |
● Conversion time (per channel) | 180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms |
Smoothing of measured values | |
● Number of smoothing levels | 4; None; 4/8/16 times |
● parameterizable | Yes |
Encoder |
|
Connection of signal encoders | |
● for voltage measurement | No |
● for current measurement as 2-wire transducer | Yes |
— Burden of 2-wire transmitter, max. | 650 Ω |
● for current measurement as 4-wire transducer | Yes |
Errors/accuracies | |
Linearity error (relative to input range), (+/-) | 0.01 % |
Temperature error (relative to input range), (+/-) | 0.005 %/K |
Crosstalk between the inputs, min. | 50 dB |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % |
Operational error limit in overall temperature range | |
● Current, relative to input range, (+/-) | 0.5 % |
Basic error limit (operational limit at 25 °C) | |
● Current, relative to input range, (+/-) | 0.3 % |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |
● Series mode interference (peak value of interference < rated value of input range), min. | 70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB |
Isochronous mode | |
Isochronous operation (application synchronized up to terminal) | No |
Interrupts/diagnostics/status information | |
Diagnostics function | Yes |
Alarms | |
● Diagnostic alarm | Yes |
● Limit value alarm | No |
Diagnostic messages | |
● Monitoring the supply voltage | Yes |
● Wire-break | Yes; at 4 to 20 mA |
● Short-circuit | Yes; Sensor supply to M; module by module |
● Group error | Yes |
● Overflow/underflow | Yes |
Diagnostics indication LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes; Green LED |
● Channel status display | Yes; Green LED |
● for channel diagnostics | No |
● for module diagnostics | Yes; green/red DIAG LED |
Potential separation | |
Potential separation channels | |
● between the channels | No |
● between the channels and backplane bus | Yes |
● between the channels and the power supply of the electronics | No |
Isolation |
|
Isolation tested with | 707 V DC (type test) |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | -30 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | -30 °C |
● vertical installation, max. | 50 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Dimensions | |
Width | 15 mm |
Height | 73 mm |
Depth | 58 mm |
Weights | |
Weight, approx. | 31 g |
last modified: | 01/20/2020 |
SIEMENS Analog Input Module 6ES7134-6GF00-0AA1